För att avgöra om övervakningssensorn för vattenkvalitet måste kalibreras kan du göra det från följande aspekter:
1. Kontrollera kalibreringscykeln
- Se sensorns instruktionshandbok eller tillverkarens rekommendationer . Olika typer av övervakningssensorer på nätet har olika kalibreringscykler . till exempel rekommenderas vanligt att kalibreras en gång varje 1-2 veckor; Medan upplösta syresensorer kan kalibreras en gång i månaden . När den angivna kalibreringscykeln uppnås, bör kalibrering övervägas .
2. Observera datakarakteristika
- Abnormal data fluctuations: If the measured data suddenly fluctuates greatly, changes irregularly, or exceeds the normal range, and factors such as water sample changes and external interference are excluded, the sensor may need to be calibrated. For example, if the conductivity sensor measurement value suddenly jumps sharply, it may be that there is a problem with the sensor performance.
- Data Drift: Sensormätningsvärdet fortsätter att avvika i en riktning och matchar inte den faktiska vattenkvaliteten . Detta kan vara så att sensorn har drivit och måste kalibreras . till exempel, de turbiditetsdata som övervakas under en lång tid är gradvis högre, medan det faktiska vattenprovet har förändrats betydligt {{{{3 {3. {{3 {3} {{3)
3. Jämförelse med andra övervakningsdata
- Comparison with other sensors: If the data of the sensor to be calibrated is significantly different from that of other related water quality sensors that are working normally in the same water sample, and other sensors are confirmed to be normal, then the sensor may need to be calibrated. For example, if the data relationship between the chemical oxygen demand (COD) sensor and the total organic carbon (TOC) sensor is obviously abnormal, while the TOC -sensordata är normalt, det är nödvändigt att överväga att kalibrera COD -sensorn .
- Comparison with laboratory test results: Regularly compare the data of the online monitoring sensor with the laboratory test results of the same sample. If the deviation exceeds the allowable range, it means that the sensor may need to be calibrated. For example, the measurement value of the online ammonia nitrogen sensor is significantly different from the laboratory spectrophotometric measurement värde .
4. Kontrollera sensorns status
Appearance inspection: Check whether there is dirt, corrosion, damage, etc. on the surface of the sensor. If there is dirt on the electrode surface, it may affect the measurement accuracy and needs to be cleaned and calibrated. If the glass electrode of the pH sensor is contaminated, it will cause inaccurate measurement.
- Performance inspection: Check the performance indicators of the sensor such as response time and stability. If the response time is significantly longer and the stability is worse, calibration may be required. For example, after the water sample is replaced, the dissolved oxygen sensor takes much longer than normal to reach a stable measurement value.
V . överväga miljöfaktorer
- Förändringar i miljöförhållanden: Om omgivningstemperaturen, luftfuktigheten, trycket och andra förhållanden för övervakningssensorn för vattenkvalitetsövervakning avsevärt, utöver det tillämpliga intervallet för sensorn, kan det påverka dess prestanda och kräva kalibrering . till exempel under varma säsonger, kan mätningsanalysen för vissa sensorer påverkas .
- Changes in water quality: When the monitored water quality composition, concentration, etc. change significantly, especially when pollutants or interfering substances that the sensor is not adapted to appear, calibration may be required. For example, the sudden appearance of high concentrations of heavy metal ions in the water may interfere with the measurement of certain ion sensors.