Försiktighetsåtgärder för att använda platin-rhodium termoelement

If the platinum-rhodium thermocouple is improperly installed and used, it will not only increase the measurement error, but also reduce the service life of the platinum-rhodium thermocouple. Therefore, the platinum-rhodium thermocouple should be correctly installed and used reasonably according to the measured temperature range and working environment.
(1) A suitable installation location should be selected. Since the temperature distribution in the heating furnace is uneven, the platinum-rhodium thermocouple measures the temperature of a local area, so a suitable measurement point should be selected to place the platinum-rhodium thermocouple. Usually, the platinum-rhodium thermocouple can be installed in a position where the temperature is relativt enhetlig och kan representera temperaturen på arbetsstycket, men det bör inte installeras bredvid ugnsdörren eller för nära värmekällan .
(2) Platsen där platin-rhodium-termoelementet är installerat bör vara så långt borta från det starka elektromagnetiska fältet som möjligt för att undvika temperaturmätningsinstrumentet som introducerar ytterligare interferenssignaler .
(3) Djupet på platin-rhodium-termoelementet som är infogat i ugnen bör inte vara mindre än 8 till 10 gånger den yttre diametern för platin-rhodium-termouselskyddsröret, och det heta slutet är så nära arbetet som möjligt, men det måste säkerställas att platinum-rhodium-thermen är inte skadad när det är belastat))
(4) Kopplingslådan i platin-rhodium-termoelementet bör inte vara nära ugnsväggen för att förhindra att den kalla ändtemperaturen är för hög . i allmänhet bör det vara cirka 200 mm från ugnsväggen .}
(5) The platinum-rhodium thermocouple should be used vertically as much as possible to prevent the protective tube from deforming under high temperature. If it needs to be installed horizontally, the insertion depth should not be greater than 500mm, and the exposed part should be supported by a rack. After a period of use, it should be rotated 180℃; För att förhindra att platin-rhodium termoelementet för överhettning kan överhettas kan en termoelement med höger vinkelrödor också användas .
(6) The gap between the platinum-rhodium thermocouple protection tube and the furnace wall should be tightly blocked with refractory materials to prevent air convection from affecting the accuracy of temperature measurement. The gap between the compensation wire and the wiring hole of the junction box should also be tightly plugged with asbestos wire and pointed downward to prevent dirt from falling in.
(7) Vid mätning av ugntemperaturen med en platin-rhodium termoelement, undvik direkt flamspray, eftersom temperaturen vid flamspraypunkten är högre än den faktiska temperaturen i ugnen och är instabil .
(8) Vid mätning av låga temperaturer, för att minska termisk tröghet för platin-rhodium-termoelementet, kan en platin-rhodium termoelement med ett öppet skyddsrör eller utan skyddsrör användas .
(9) Under platin-rhodium-termoelementets livslängd bör termoden och skyddsröret regelbundet kontrolleras för att se om de är i gott skick . Om pittning, stains, lokal diameter bör reduktion eller allvarlig korrosion på ytan av skyddsröret finns på ytan av platinum-rhodium-gruppen Platinum-Rhodium termoelement .