I elektrokemisk impedansspektroskopitestning, hur kan man avgöra om beläggningen är skadad?

I det elektrokemiska impedansspektroskopi (EIS) -testet kan följande aspekter användas för att avgöra om TEFLON -beläggningen är skadad:
Egenskaper för impedansspektrum
Changes in capacitive arc in high frequency region: In the Nyquist plot, the capacitive arc in high frequency region is usually related to the insulation performance of the coating. A complete coating has a higher resistance, which is manifested as a larger capacitive arc. When the coating is damaged, the radius of the capacitive arc in the high frequency region will decrease, because the damaged part gör det enklare för elektrolyten att kontakta underlaget, vilket resulterar i en minskning av beläggningsmotståndet .
Utseendet på induktiv båge i lågfrekvensområdet: Under normala omständigheter kommer impedansspektrumet för den kompletta beläggningen inte att visa uppenbar induktiv båge i lågfrekvensområdet . när beläggningen är skadad, metallsubstratet exponeras för elektrolyten och en korrosionsreaktion inträffar, vilket kan orsaka en induktiv arc i lågfrekvensregionen Adsorptionen och desorptionen av mellanprodukter eller korrosionsprodukter som producerats under korrosionsprocessen på elektrodytan .
Förändringar i impedansspektrumparametrar
Coating resistance (Rc) decreases: Coating resistance is an important parameter reflecting the barrier performance of the coating. If the coating resistance value obtained by equivalent circuit fitting is significantly lower than the previous test result, it means that the integrity of the coating is damaged and there may be a damage point, making it easier for the current to pass through the coating to reach the substrate.
Increased coating capacitance (Cc): The coating capacitance is related to the thickness and dielectric constant of the coating. When the coating is damaged, the contact area between the coating and the electrolyte increases, which is equivalent to an increase in the plate area of ​​​​the capacitor, and the effective thickness of the coating decreases, all of which will lead to an increase in the coating capacitance värde .
Jämförelse med standardspektra eller empiriska data
Compare the impedance spectrum obtained by the test with the known standard spectra of intact coatings and damaged coatings. If the test spectrum is similar to the standard spectrum of the damaged coating, such as a significant decrease in high-frequency capacitive reactance arc and the appearance of inductive reactance characteristics at low frequencies, it can be judged that the coating is skadad . Dessutom är det också möjligt att analysera om det nuvarande impedansspektrumet uppfyller egenskaperna för beläggningsskador baserat på tidigare experimentell erfarenhet och data och gör en bedömning .
Det bör noteras att en enda funktion kanske inte är tillräcklig för att exakt avgöra om beläggningen är skadad . Det är nödvändigt att helt och hållet betrakta de grafiska egenskaperna för impedansspektrumet, parameterförändringar och jämförelse med standardspektra eller empiriska data för att dra en mer exakt slutsats .) övervägas under analysen .